Prekių katalogas

Dujinis degiklis su žarna ir antgaliais 1500~1800°C

  • Dujinis degiklis su žarna ir antgaliais 1500~1800°C

    Kodas: 73340
    2402 
    Šią prekę turime sandėlyje.
    Į krepšelį 

    Pusiau profesionali linija.

    Prekės ženklas
    VOREL
  • LIEPSNA TEMP.1500 ° C ~ 1800 ° C,
    šilumos energijos ~ 28KW;
    GAMTINIŲ DUJŲ SĄNAUDOS 2000 G / H;
    su liepsnos- DUJŲ reguliavimu;
    Žarnos ilgis: 2M

    Product description
    Long roofing burner with 50mm nozzle, designed for people covering large areas of roofs with thermo-weldable roofing paper. The length of the burner allows you to work in a standing position, high thermal efficiency / nozzle fi 50 /, greatly speeds up the work. The handle has a special valve closing the gas supply when the burner is put away. This solution causes a large saving of gas consumption.

    TECHNICAL PARAMETERS:
    • Number of goblets of burners - 1
    • Size of goblets [mm] - 50
    • Nominal gas pressure [MPa] - 1.2
    • Flame temperature [ºC] - 1500-1800
    • Nominal stream [g / h] - 2000
    • Thermal load [kW] - 28
    • Hose length [m] - 2
    • Length of the burner (without hose length) [mm] - 745
    Purpose / use
    The gas burner is designed for roofing work. Thanks to the power supply using a bottle with compressed butane (it is also possible to supply a mixture of propane and butane gas) it is possible to work in places without energy sources.
    Usage
    The device should be installed in accordance with the operating instructions. Tighten the hose to the assembled device. Connect the other end of the hose to the gas bottle.
    Tightness check connections by unscrewing the cylinder valve slightly, then apply soap water to the connections. In case of gas bubbles, turn off the gas supply and tighten the leaky connections. Repeat the procedure until complete gas tightness is ensured

    Unscrew the gas valve in the cylinder and then unscrew the valve of the device, but only enough to allow the gas outlet. Ignite the gas at the outlet of the cup. For this purpose, use a special lighter designed to ignite portable gas burners. After approx. 20 seconds, press the lever of the burner). In case of too short a flame, set the gas pressure using the burner valve. After releasing the lever the flame will return to the economy mode.
    After finishing work, close the cylinder valve and then, after extinguishing the flame, set aside the burner on the non-flammable substrate to cool. After cooling, proceed with maintenance.

    Details of assembly, operation and maintenance of the device in the enclosed operating instructions.
    Contents of the package
    • Burner (G3 / 8 "-19) with 50mm nozzle
    • 2 m hose (G3 / 8 "-19, 21.8-14)
    Technical data
    Index number 73341
    EAN 5906083733413
    Brand Vorel
    PCS unit
    Gross weight (kg) 1.3000
    Master Carton MC 20
    Pal 120


    FLAME TEMP. 1500°C~1800°C; HEAT POWER ~28KW; GAS CONSUMPTION 2000 G/H; GAS TORCH WITH FLAME ADJUSTMENT; HOSE LENGTH: 2M
    BURNER DIA.: 50MM; CONNECTOR LENGTH 50CM